STRPDC-0816
TECHNICAL AND PERFORMANCE DATA
PRESSURE DROP CHARTS
f
WYE & BASKET STRAINERS
TITAN
TITAN FLOW CONTROL, INC.
WYE Strainers - Small Models
WYE Strainers - Large Models
Models: YS12 - YS52 - YS55 - YS56 - YS81 - YS82
Models: YS58 - YS59 - YS54 - YS61 - YS62 - YS63 - YS64 - YS65
Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)
Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)
20 30 40 50 70 100 200 300 500 700 1000 2000 3000 5000 10000 20000
50000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
1
2
3
4
5
6
7
10
2
2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
110
160
260
400
570
950
1600
2200
3300
4900
6100
8000
11000
70
C v
Sizes (in):
C v
0.2 0.3 0.5 0.7 1
2 3 4 5 6 7 8 10
20 30 4050 70 100 200 300 500 7001000
0.1
0.2
0.3
0.4
0.5
0.7
1
2
3
4
5
6
7
10
1/4
3/8
1/2
3/4
1
1 1/4
1 1/2
2
2 1/2
3
2
8
15
22
38
42
70
110
160
0.7
C v
Sizes (in):
C v
WYE Strainers - High Pressure - Class 900 &1500
WYE Strainers - High Pressure - Class 2500
Models: YS66 - YS67 - YS68 - YS69 - YS83 - YS84
Models: YS70 - YS71 - YS85 - YS86
Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)
Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)
1
2 3 4 5 6 7 8 10
20 30 4050 70 100 200 300 500 700 1000 20003000 5000
0.1
0.2
0.3
0.4
0.5
0.6
0.7
1
2
3
4
5
6
7
10
3/4
1
1 1/4
1 1/2
2 1/2 - 3
4
6
8
10
6
16
32
34
60
140
180
450
650
930
11
1/2
C v
C v
2
Sizes (in):
5 6 7 8 10
20 30 40 50 6070 100
200 300 400500 700 1000
2000
0.1
0.2
0.3
0.4
0.5
0.7
1
2
3
4
5
6
7
10
1 1/2
2
3
4
6
8
Sizes (in):
42
100
160
375
600
30
C v
C v
•
These curves are theoretical; actual results may vary depending on installation conditions and other variables. Use these values for reference only.
•
The above pressure drop charts are based upon 1/8" perforated screens and baskets handling clean water at 60 °F during ideal inlet and outlet conditions. Therefore, they
should only be used for estimation purposes.
•
For fluids other than water, multiply the pressure drop (Δ P) obtained from the charts by the specific gravity of the fluid in question.
•
For mesh lined screens, multiply the pressure drop (Δ P) obtained from the charts by the corresponding correction factor shown in the Cv correction table.
Tel: 910-735-0000
s
Fax: 910-738-3848
s
titan@titanfci.coms
www.titanfci.com290 Corporate Drive
s
PO Box 7408
s
Lumberton, NC 28358
TITAN FLOW CONTROL, INC.
Pressure Drop Equation for Liquids:
Δ P = G × (Q / Cv)
2
× Cr
Δ P = Pressure drop (psi)
G = Specific gravity of liquid
Q = Flow rate (GPM)
Cv = Flow coefficient factor Cr = Correction factor for mesh and viscosity