TITAN FLOW CONTROL CATALOG - 0724

STRPDC-0121

TECHNICAL AND PERFORMANCE DATA PRESSURE DROP CHARTS f WYE & BASKET STRAINERS

TITAN

TITAN FLOW CONTROL, INC. WYE Strainers - Small Models Models: YS12 - YS52 - YS55 - YS56 - YS81 - YS82

WYE Strainers - Large Models

Models: YS58 - YS59 - YS54 - YS61 - YS62 - YS63 - YS64 - YS65

Sizes (in):

Sizes (in):

2 1/2

3/4

1

1 1/2

2

1/4

3

1/2

1 1/4

3/8

24

12

18

16

20

10

14

5

6

8

4

3

2 1/2

2

10

10

5 6 7

3 4 5 6 7

4

3

2

2

C v

C v

C v

C v

70

2200

4900

950

1600

6100

8000

3300

11000

570

400

260

160

110

1

22

42

70

110

38

15

2

160

8

0.7

1

0.3 0.4 0.5 0.6 0.7

0.7

0.5

0.4

0.3

0.2

0.2

0.1

0.1

20 30 40 50 70 100 200 300 500 700 1000 2000 3000 5000 10000 20000

50000

0.2 0.3 0.5 0.7 1

2 3 4 5 6 7 8 10

20 30 40 50 70 100 200 300 500 700 1000

Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)

Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)

WYE Strainers - High Pressure - Class 900 &1500

WYE Strainers - High Pressure - Class 2500

Models: YS66 - YS67 - YS68 - YS69 - YS83 - YS84

Models: YS70 - YS71 - YS86

Sizes (in):

Sizes (in):

8

10

3/4

6

1

1 1/2

1 1/4

10

1/2

1 1/2

2 1/2 - 3 4

4

6

2

8

3

2

10

3 4 5 6 7

5 6 7

4

3

2

2

C v

C v

C v

C v

1

450

30

42

600

100

375

160

34

650

6

32

60

930

180

140

11

16

1

0.3 0.4 0.5 0.6 0.7

0.7

0.5

0.4

0.3

0.2

0.2

0.1

0.1

1

2 3 4 5 6 7 8 10

20 30 40 50 70 100 200 300 500 700 1000 2000 3000 5000

5 6 7 8 10

20 30 40 50 60 70 100

200 300 400 500 700 1000

2000

Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)

Legend: Pressure Drop - PSI (y - axis) versus Flow Rate - GPM (x -axis)

Pressure Drop Equation for Liquids: ∆ P = G × (Q / Cv) 2 × Cr

∆ P = Pressure drop (psi)

G = Specific gravity of liquid

Q = Flow rate (GPM)

Cv = Flow coefficient factor Cr = Correction factor for mesh and viscosity

• These curves are theoretical; actual results may vary depending on installation conditions and other variables. Use these values for reference only. • The above pressure drop charts are based upon 1/8" perforated screens and baskets handling clean water at 60 °F during ideal inlet and outlet conditions. Therefore, they should only be used for estimation purposes. • For fluids other than water, multiply the pressure drop (∆ P) obtained from the charts by the specific gravity of the fluid in question. • For mesh lined screens, multiply the pressure drop (∆ P) obtained from the charts by the corresponding correction factor shown in the Cv correction table.

Tel: 910-735-0000 s Fax: 910-738-3848 s titan@titanfci.com s www.titanfci.com 290 Corporate Drive s PO Box 7408 s Lumberton, NC 28358 TITAN FLOW CONTROL, INC.

Made with FlippingBook - Online catalogs